Features |
Values/ Standards |
Starting |
DOL for all Or Star delta for frames 100 & above. |
Permissible starts/hr |
2 Hot / 3 Cold / 4 Equally spread |
Loading at reduced volts |
75% Rated volts for 5 minutes |
Insulation / temp. Rise |
Class ‘F’/70 deg C |
Direction of rotation |
Bi-Directional |
No. Of leads |
3 up to 90 frame & 6 for including and above 100 frame |
Connection |
Star up to 90 frame and , Delta including and above 100 frame |
Degree of protection |
IP55, IP 66 on request. |
Method of cooling |
IC 411 |
T.box position |
Top TB Standard and side TB – optional ( RHS from DE) |
Bearing life |
40,000 hours for direct drive, 20,000 hours for belt drive |
Vibration |
Normal class as per IS 12075 |
Noise |
As per IS 12065. |
Construction |
Foot, ‘B’ flange, ‘C’ flange, Foot cum ‘B’ flange , Foot cum ‘C’ flange |
Frame sizes |
Ravi series 63-315 |
Mounting arrangement |
Multiple mounting holes in same body, S/M/L as per standard |
Shaft extension |
Single cylindrical extension as per IS 1231 |
Body material |
CI from 63-315 frame |
T.box material |
Nylon Up to 132 frame /sheet metal 160 frame and above |
Fan material |
Polypropylene up to 225frame/ 250 and above fabricated steel |
Accessories |
Nil, Thermistor, space heater, winding RTD, BTD on request in select frames. |
Paint & shade |
Standard Motor |
Main body : Shade RAL 1020 |
Fan cover : Shade 592 of IS 5 International orange |
Bearing type and Greasing facility |
Sealed Bearings grease lubricated for life up to 225 frame and open bearings with online greasing facility in 250 and above frames. |